2-31-011

STA3 Alarm Horn with Xenon & LED Tower

The STA3 is a customisable audio-visual signal featuring a tower of 3 AlertAlight L101 type beacons combined with a SONF1 alarm sounder.

Each beacon position can contain either a Xenon or high output L.E.D. light source. The STA3 assembly features a pre-wired junction box and cable loom enabling the end user to determine beacon type and position during installation.

Specification

 
General:
Cable entries: 2 x M20 clearance
Ingress Protection: IP66
Housing material: UL94V0 & 5VA FR ABS
Housing colour: RAL3000 Red, RAL7038 Grey and White
Lens material: PC
Fixings: Stainless Steel
Operating temp: -25° to +55°C [-13° to +131°F]
Storage temp: -40° to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°f]
STA2 Weight: 0.95kg/2.09Ibs
STA3 Weight: 1.15kg/2.53Ibs
STA4 Weight: 1.35kg/2.97Ibs
SONF1 - Alarm Sounder:
Maximum output: 100dB(A) @ 1 metre [91dB(A) @ 10ft/3m]
Nominal output: 99dB(A) @ 1m +/- 3dB - Tone 1 [90dB(A) @ 10ft/3m]
No. of tones: 10 (UKOOA / PFEER compliant)
No. of stages: 2 (AC voltage variants 1 stage)
Volume control: On board potentiometer
Effective range: 30m/99ft @ 1KHz
Monitoring: Reverse polarity diode protection on DC units.
Terminals: 0.5 to 1.5mm² cables.
L101X - Xenon:
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
Peak Candela: 500,000 cd - calculated from energy (J)
Effective Intensity cd: 250 cd - calculated from energy (J)
Peak Candela: 86,935 cd* - measured ref. to I.E.S.
Effective Intensity cd: 200 cd* - measured ref. to I.E.S.
Terminals: 0.5 to 4.0mm² cables.
Lens colours: Amber, Blue, Clear, Green, Opal, Red, Yellow
Tube life: Emissions are reduced to 70% after 8 million flashes
L101H - L.E.D:
Light source: High intensity L.E.D. array.
24 x Superflux type high ouput L.E.D’s
Options: Steady or 2Hz flash mode (on board selection)
Peak/Effective Intensity cd: Green L.E.D: 176cd - measured ref. to I.E.S.
Terminals: 0.5 to 4.0mm² cables
L.E.D. colours: Amber Blue, Green, Red and White
Lens colour: All L.E.D. colours use a Clear lens to maximise output and to ensure the signal is most effective in high ambient light levels.

Part Codes

Version: Description: Voltage: Part code:
STA3 Junction box & SONF1 assy
for 3 x L101 beacons
12/24Vdc STA3DC024[x]
STA3 Junction box & SONF1 assy
for 3 x L101 beacons
115Vac STA3AC115[x]
STA3 Junction box & SONF1 assy
for 3 x L101 beacons
230Vac STA3AC230[x]
[x]: G=Grey, R=Red, W=White
 
Version: Description: Voltage: Part code:
ST-L101X L101 Xenon Beacon 5J 12Vdc ST-L101XDC012[x]
ST-L101X L101 Xenon Beacon 5J 24Vdc ST-L101XDC024[x]
ST-L101X L101 Xenon Beacon 5J 115Vac ST-L101XAC115[x]
ST-L101X L101 Xenon Beacon 5J 230Vac ST-L101XAC230[x]
ST-L101H L101 L.E.D. Beacon 10-30Vdc ST-L101HDC030[x]
ST-L101H L101 L.E.D. Beacon 90-260Vac ST-L101HAC230[x]
[x]: A=Amber, B=Blue, C=Clear, G=Green, R=Red
Example: For a tower of A SONF1 alarm sounder plus three beacons using two Xenon beacons,
one red, one amber plus one L.E.D. beacon in green using a 24Vdc supply in a red housing,
order the following part codes:
STA3DC024R
ST-L101XDC024R
ST-L101XDC024A
ST-L101HDC024G
For UL approved version suffix all relevant part codes with '-UL'

L101H L.E.D. Beacon

Version: Voltage: Current:
DC   10-30V dc 155mA (24V dc)
AC/DC 50/60Hz 90-260V ac/dc (230V ac)

L101X Xenon Beacon

Version: Voltage: Current:
12V dc 10-14V 500mA/380mA
24V dc 20-28V 250mA/300mA
115V ac 50/60Hz +/-10% 70mA
230V ac 50/60Hz +/-10% 35mA

SONF1 Alarm sounder

Version: Voltage: Current:
24V dc 10-30V 25mA
115V ac 50/60Hz +/-10% 13mA
230V ac 50/60Hz +/-10% 13mA

Tone Table

Stage 1 WAV file Frequency Description Stg 2
T 1   800/1000Hz @ 0.25 sec Alternating T 8
T 2   500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop T 1
T 3   1200/500Hz @ 1Hz - DIN / PFEER P.T.A.P. T 8
T 4   544Hz (100mS)/440Hz (400mS) - NF S 32-001 T 9
T 5   Bell T 1
T 6   800/1000Hz @ 7Hz Sweeping T 8
T 7   500-1200Hz 3.75sec /0.25sec. Australian Evac. T 10
T 8   1000Hz Continuous - PFEER Toxic Gas
T 9   Continuous 554Hz
T 10   420Hz @ 0.625 sec Australian Alert
 
Where applicable following tones are available on AC voltage versions:
Stage 1   Frequency Description
T 1   800/1000Hz @ 0.25 sec Alternating
T 2   500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop
T 3   1200/500Hz @ 1Hz - DIN / PFEER P.T.A.P.
T 4   544Hz (100mS)/440Hz (400mS) - NF S 32-001
T 5   1000Hz Continuous - PFEER Toxic Gas
T 6   Bell
T 7   800/1000Hz @ 7Hz Sweeping
T 8   2400/2900Hz @ 50Hz Sweeping
T 9   420Hz @ 0.625 sec Australian Alert
T 10   500-1200Hz 3.75sec /0.25sec. Australian Evac.
Country specific or custom tone configurations and alarm frequencies are available upon request.