BSP007N , Balluff Cảm biến áp suất –1...2 bar, Balluff Vietnam, BSP007N BSP V002-IV003-A01A0B-S4
Xuất sứ: UK
Nhà cung cấp: STC Vietnam
Hãng sản xuất: Balluff
CÔNG TY TNHH TM DV SONG THÀNH CÔNG
Số 10, Lô O, KDC Miếu Nổi, Phường 3 Q.Bình Thạnh, TPHCM
Nguyễn Văn Khá
Hotline : 0916 635 755
Email : kha@songthanhcong.com
Zalo : 0916 635 755
Skype : Văn Khá_STC
Chúng tôi là công ty hàng đầu chuyên Xuất-Nhập khẩu các thiết bị như: Absocoder, Current Transformer, Màn hình HMI, ACB, MCB, Inverter, Handheld thermometer, Pressure transmitter, Flow metter,…
Chúng tôi mong muốn được hợp tác thành công và lâu dài với quý khách!
Vaisala Vietnam | Code: HMT330 7S1D001BXAA100A1DAABAA1 |
Humidity and Temperature Transmitter; Transmitter type: HMT337 for high humidities; Probe cables: Probe 2m +180C | |
Additional temperature probe: 2m, -70..+180°C 1/4 DIN Class B | |
Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro; No display, power supply : Standard (10...35V,24VAC) | |
Signal output: Analog Output 4...20mA; Analog output signals for Ch1: 0...100%RH; Analog output signals for Ch2: Special (pls confirm as placing order); Output units: Metric Units; Option for module slot 1&2: no module; Cable bushings: Sealed Cable Gland M20x1.5; Transmitter installation: Wall Mounting Kit; Humidity sensor: Heated composite sensor; Sensor protection: PPS Grid with Steel Netting; No Installation Kit, No Accessories | |
Vaisala Vietnam | Humidity and Temperature Transmitter |
Code: HMT330 7S1D011BXAA100A45CQBAA1 | |
Transmitter type: HMT337 for high humidities | |
Probe cables: Probe 2m +180C | |
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display | |
Power supply: Standard with Galvanic Isolation Module | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: 0...100%RH | |
Analog output signals for Ch2: Special – pls confirm and make clear as order ; No Analog output signals for Ch3 | |
Analog output range for temperature: no T range | |
Output units: Metric Units; No Option for module slot 1&2 | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
Transmitter installation: DIN Rail Clips with Installation Plate | |
Humidity sensor: Heated composite sensor HUMICAP180C | |
Sensor protection: Sintered Filter AISI 316L HM47280 | |
Installation kit for probe: Swagelok for 12mm Probe 1/2" NPT Thread ; User´s Guide HMT330 English | |
No PC Accessories ; No Calibration Contract ISO9001 Calibration | |
Vaisala Vietnam | Code: HMT330 7S0A001BCAE200A0AACBCA1 |
Humidity and Temperature Transmitter | |
Transmitter type: HMT337 for high humidities | |
Probe cables: 2m +180C; No Additional temperature probe | |
Calculations: Code RH+T, No Display | |
Power supply: Standard (10...35V,24VAC) | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: 0...100%RH | |
Analog output signals for Ch2: Temperature Range -40...+180C | |
No Analog output signals for Ch3 | |
Output units: Non Metric Units | |
Option for module slot 1 &2: No Module | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
No Transmitter installation | |
Humidity sensor: General purpose HUMICAP180R | |
Sensor protection: PPS Grid with Steel Netting | |
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English | |
PC Accessories: MI70LINK PC Software with RS232 Serial Cable with D9 Female Connector | |
No Calibration Contract ISO9001 Calibration | |
No Maintenance Contract | |
Vaisala Vietnam | Humidity and Temperature Transmitter |
Code: HMT330 7S1D001BBBB211A15ACBBA1 | |
Transmitter type: HMT337 for high humidities | |
Probe cables: Probe 2m +180C | |
Additional temperature probe: T-probe, 2m, -70..+180°C 1/4 DIN Class B; Calculations: Cod RH+T+Td+a+Tw+x+h+pws With warmed RH-pro+T-pro ; No Display | |
Power supply: Standard (10...35V,24VAC) | |
Signal output: Analog Output 4...20mA | |
Analog output signals for Ch1: 0...100%RH | |
Analog output signals for Ch2: 0...100%RH | |
Analog output signals for Ch3: 0...100%RH | |
Analog output range for temperature: Temperature Range -40...+60C ; Output units: Non Metric Units | |
Option for module slot 1: Relay Module | |
Option for module slot 2: Relay Module | |
Cable bushings: Sealed Cable Gland M20x1.5 | |
Transmitter installation: Wall Mounting Kit | |
Humidity sensor: Heated composite sensor HUMICAP180C | |
Sensor protection: PPS Grid with Steel Netting | |
Installation kit for probe: Duct Installation Kit For HMT333 and HMT337 ; User´s Guide HMT330 English | |
PC Accessories: RS232 Serial Interface Cable with D9 Female Connector ; No Calibration Contract ISO9001 Calibration | |
No Maintenance Contract |