lms100-10000-2d-lidar-sensors-sick.png
  • FEATURES
    Application Indoor
    Light source Infrared (905 nm)
    Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
    Aperture angle  
    Horizontal 270°
    Scanning frequency 25 Hz / 50 Hz
    Angular resolution

    0.25°

    0.5°

    Heating No
    Working range 0.5 m ... 20 m
    Scanning range  
    At 10% remission 18 m
    At 90% remission 20 m
    Amount of evaluated echoes 2
    Fog correction Yes
  • AMBIENT DATA
    Object remission 2 % ... > 1,000 % (reflectors)
    Electromagnetic compatibility (EMC) EN 61000-6-2:2005 / EN 61000-6-4 (2007-01)
    Vibration resistance EN 60068-2-6 (1995-04)
    Shock resistance EN 60068-2-27 (1993-03)
    Ambient operating temperature 0 °C ... +50 °C
    Storage temperature –30 °C ... +70 °C
    Ambient light immunity 40,000 lx
  • INTERFACES
    Ethernet ✔ , TCP/IP
    Remark OPC
    Function Host
    Data transmission rate 10/100 MBit/s
    Serial ✔ , RS-232
    Function Host, AUX
    Data transmission rate 9.6 kBaud ... 115.2 kBaud
    CAN
    Function Extension of outputs
    Digital inputs 2 digital and 2 encoder inputs
    Digital outputs 3
    Optical indicators 7-segment display (plus 5 LEDs showing device status, contamination warning and initial condition)
  • PERFORMANCE
    Response time ≥ 20 ms
    Detectable object shape Almost any
    Systematic error ± 30 mm 1)
    Statistical error 12 mm 1)
    Integrated application Field evaluation with flexible fields
    Number of field sets 10 fields
    Simultaneous evaluation cases 10
    • 1) Typical value, actual value depends on environmental conditions.
  • MECHANICS/ELECTRONICS
    Electrical connection 1 x system plug with screw terminal block
    Supply voltage 10.8 V DC ... 30 V DC
    Power consumption Typ. 8 W
    Housing color Light blue (RAL 5012)
    Enclosure rating IP65 (EN 60529, Section 14.2.5)
    Protection class III (EN 50178 (1997,10))
    Weight 1.1 kg
    Dimensions (L x W x H) 105 mm x 102 mm x 152 mm