E2xBL2 E2S Vietnam Đèn Led nhiều chức năng _ Multi-function LED Beacon & Status Light
Xuất sứ: UK
Nhà cung cấp: STC Vietnam
Hãng sản xuất: 1) E2S VIETNAM
Ứng dụng sản phẩm: Các ngành sản xuất
E2xBL2 Multi-function LED Beacon & Status Light
The hazardous location E2xBL2 LED beacon and status light is UL/cULs approved for Class I Div 2, Class II Div 2, Class I Zone 2/22 as well as IECEx and ATEX certified for Zone 2 and 22 applications.
The hazardous area E2xBL2 LED status light & beacon utilises an array of high power Cree® LED's, orientated to optimise visibility in any direction. The beacon can be configured as a steady beacon for status indicator use, with a light output of up to 87 candela. Alternatively one of the five flashing modes, with a light output of up to 160 candela, may be used for warning applications. DC voltage versions feature three remotely selectable stages enabling multiple warnings to be signalled from one device. The UV stable colour filter enhances the light output and is field replaceable.
Specification
Source: | Array of 4 x High Power Cree® LED's |
Modes: | 1Hz flash (60 fpm) 1.5Hz flash (90 fpm) 2Hz flash (120 fpm) Double strike flash Triple strike flash High Power Steady Low Power Steady |
Eff. Intensity cd: | 87 cd - High Power Steady |
Eff. Intensity cd: | 160 cd - 1Hz flash |
Lens colours: | Amber, Blue, Clear, Green, Magenta, Red & Yellow |
Voltages DC: | 24V dc (18-54V dc) |
Voltages AC: | 115V ac; 230V ac |
Ingress protection: | IP rating per EN60079-0:IP64 IP rating per EN60529:IP66 Type rating per UL50E/NEMA250:4/4X/13 |
Enclosure material: | UL94V0 PPS & ABS |
Lens material: | Borosilicate glass dome with PC prismatic lens cover. |
Guard: | Stainless Steel dome guard as standard |
Cable entries: | Dual M20x1.5 or 1/2"NPT |
Terminals: | 0.5 - 2.5mm² (20-14 AWG) |
Line monitoring: | Blocking diode included EOL can be factory fitted |
LED life: | 60,000 hours |
Operating temp: | -20 to +55°C [-4° to +131°F] |
Storage temp: | -40 to +70°C [-40° to +158°F] |
Relative humidity: | 90% at 20°C [68°F] |
Weight: | 1.48kg/3.25Ibs |
* All candela data is representative of performance with clear lens at optimum voltage. |
Current Consumption
Version: | Voltage: | Steady High Power Current: |
Steady Low Power Current: |
Flashing 1Hz Current: |
---|---|---|---|---|
24V dc | 18-54V dc | 240mA | 134mA | 110mA |
115V ac | 103.5-126.5V ac 50/60Hz | 95mA | 78mA | 90mA |
230V ac | 207-253V ac 50/60Hz | 48mA | 37mA | 45mA |
Part Codes
Part Code: | Ident.: | Description: | |
---|---|---|---|
Product type: | E2xBL2 | LED Beacon/Status Light | |
Voltage: | AC115 AC230 DC024 |
115V ac 50/60Hz 230V ac 50/60Hz 24V dc (18-54Vdc) |
|
Cable entries: [e] | A B C |
M20x1.5 & ½” NPT M20x1.5 & M20x1.5 ½” NPT & ½” NPT |
|
Stopping plug material: [m] | N | Nylon | |
Bracket & Guard: [s] | 1 2 |
304 (A2) Stainless Steel 316 (A4) Stainless Steel |
|
Version: [v] | A1 | UL, cULs, IECEx & ATEX | |
Enclosure: [x] | B | Black | |
Lens colour: [y] | A, B, C G, M, R Y |
Amber, Blue, Clear Green, Magenta, Red Yellow |
|
e.g: E2xBL2DC024BN1A1B/R | E2xBL2 LED Beacon in 24Vdc with dual M20 entries, nylon stopping plug, UL, cULs, IECEx & ATEX approved Black enclosure with Red lens |
||
Also available as the E2xC1X05 combined alarm sounder and Xenon beacon and the E2xC1LD2 combined alarm sounder and LED beacon. |
Coding
- ATEX / IECEx certification
II 3G Ex nA IIC Gc T4 Ta -20°C to +55°C
II 3D Ex tb IIIC Dc T85°C Ta -20°C to +55°C - NEC Class / Zone ratings US
Class I Zone 2 AEx nA IIC Gc T4 Ta -20°C to +55°C
AEx tb IIIC Dc T85°C Ta -20°C to +55°C - CEC Class / Zone ratings Canada
Ex nA IIC Gc T4 Ta -20°C to +55°C
Ex nA IIC Gc T4A Ta -20°C to +40°C
Ex tb IIIC Dc T85°C Ta -20°C to +55°C - NEC & CEC Class / Division Ratings for US / Canada
Class I, Div 2, ABCD T4A Ta -20°C to +55°C
Class II, Div 2, FG T6 Ta -20°C to +55°C
Class III, Div 1&2 Ta -20°C to +55°C
Multi-function patterns
Stage 1: [On board] |
Stage 2: [Remote] |
Stage 3: [Remote] |
|
---|---|---|---|
Steady High Power | Flashing 1Hz | Triple Strike | |
Steady Low Power | Flashing 1Hz | Triple Strike | |
Flashing 1Hz | 2x Flash 2Hz | Triple Strike | |
Flashing 1.5Hz | Flashing 2Hz | Double Strike | |
Flashing 2Hz | Triple Strike | Triple Strike | |
Double Strike | Steady High Power | Triple Strike | |
Triple Strike | Flashing 2Hz | Double Strike | |
Note: Remote second and third stage on DC units only |