E2xS1F Ex E2S Vietnam Loa báo động 116dB(A) _Không tia lửa_ Alarm Sounder/Horn
Xuất sứ: UK
Nhà cung cấp: STC Vietnam
Hãng sản xuất: 1) E2S VIETNAM
Ứng dụng sản phẩm: Các ngành sản xuất
E2xS1F Alarm Sounder/Horn
The hazardous area E2xS1F alarm horn sounder is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.
With a nominal sound level output of 116dB(A) at 1 metre and a choice of 45 alarm tones and 3 remotely selectable stages the E2xS1F alarm sounder horn is suitable for all general signalling duties.
The E2x range features enclosures manufactured from lightweight, corrosion proof PPS and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.
Specification
Maximum output: | 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m] |
Nominal output: | 113dB(A) @ 1m +/- 3dB - Tone 2 [104dB(A) @ 10ft/3m] |
No. of tones: | 45 (UKOOA/PFEER compliant) |
No. of stages: | 3 |
Volume control: | Max. 113dB(A); Min. 105dB(A) - Tone 2 |
Effective range: | 100m/328ft @ 1KHz |
Voltages DC: | 24Vdc (10-30Vdc); 48Vdc |
Voltages AC: | 115Vac; 230Vac |
Ingress protection: | IP rating per EN60079-0:IP64 IP rating per EN60529:IP66 Type rating per UL50E/NEMA250:4/4X/13 |
Enclosure material: | UL94V0 PPS & ABS |
Lens material: | Borosilicate glass dome with PC prismatic lens cover. |
Guard: | Stainless Steel dome guard as standard |
Cable entries: | Dual M20x1.5 or 1/2"NPT |
Terminals: | 0.5 - 2.5mm² (20-14 AWG) |
Line monitoring: | Blocking diode included EOL can be factory fitted |
Operating temp: | -20 to +55°C [-4° to +131°F] |
Storage temp: | -40 to +70°C [-40° to +158°F] |
Relative humidity: | 90% at 20°C [68°F] |
Weight: | DC: 2.5kg/5.5Ibs AC: 3.00kg/6.6Ibs |
*SPL data +/-3dB(A). Measured at optimum voltage. |
Current Consumption
Version: | Voltage: | Current: | |
---|---|---|---|
24V dc | 10-30vdc | 284mA | |
48V dc | 38-58vdc | 146mA | |
115V ac | 50/60Hz | +/-10% | 104mA |
230V ac | 50/60Hz | +/-10% | 54mA |
Part Codes
Part Code: | Ident.: | Description: | |
---|---|---|---|
Product type: | E2xS1 | E2xS1 alarm horn sounder | |
Flare type: | F | Flare Horn | |
Voltage: | AC115 AC230 DC024 DC048 |
115V ac 50/60Hz 230V ac 50/60Hz 24V dc (10-30V dc) 48V dc |
|
Cable entries: | A B C |
M20x1.5 & ½” NPT M20x1.5 & M20x1.5 ½” NPT & ½” NPT |
|
Stopping plug material: | N | Nylon | |
Bracket: | 1 2 |
304 (A2) Stainless Steel 316 (A4) Stainless Steel |
|
Approvals: | A1 | UL, cULs, IECEx & ATEX | |
Enclosure: | B | Black | |
e.g: E2xS1FAC230AN1A1B | E2xS1 alarm horn sounder with flare horn in 230Vac with one M20 cable entry and one 1/2"NPT entry. Approved to IECEx, ATEX & UL. Black enclosure. |
||
NOTE: | The E2xS1F supersedes the E2xS112 alarm horn sounder and remains compatible with all existing installations |
Coding
- IECEx / ATEX:
II 3G Ex nA IIC T4 Gc Ta -20°C to +55°C
II 3D Ex tc IIIC T85°C Dc Ta -20°C to +55°C - NEC Class / Zone ratings US:
Class I Zone 2 AEx nA IIC T4 Gc Ta -20°C to +55°C
Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +55°C - CEC Class / Zone ratings Canada
Ex nA IIC T2 Gc Ta -20°C to +55°C
Ex tc IIIC 85°C Dc Ta -20°C to +55°C - NEC & CEC Class / Division Ratings for US / Canada
Class I, Div 2, ABCD T3C Ta -20°C to +55°C
Class I, Div 2, ABCD T4 Ta -20°C to +40°C
Class II, Div 2, FG T6 Ta -20°C to +55°C
Class II, Div 2, FG T6 Ta -20°C to +55°C
Tone Table
Stage 1 | WAV file | Frequency Description. | Stage 2 | Stage 3 |
---|---|---|---|---|
T 1 | ↓ | 340 Hz Continuous | T 2 | T 5 |
T 2 | ↓ | 800/1000Hz @ 0.25 sec Alternating | T 17 | T 5 |
T 3 | ↓ | 500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop | T 2 | T 5 |
T 4 | ↓ | 800/1000Hz @ 1Hz Sweeping | T 6 | T 5 |
T 5 | ↓ | 2400Hz Continuous | T 3 | T 20 |
T 6 | ↓ | 2400/2900Hz @ 7Hz Sweeping | T 7 | T 5 |
T 7 | ↓ | 2400/2900Hz @ 1Hz Sweeping | T 10 | T 5 |
T 8 | ↓ | 500/1200/500Hz @ 0.3Hz Sweeping | T 2 | T 5 |
T 9 | ↓ | 1200/500Hz @ 1Hz - DIN / PFEER P.T.A.P. | T 15 | T 2 |
T 10 | ↓ | 2400/2900Hz @ 2Hz Alternating | T 7 | T 5 |
T 11 | ↓ | 1000Hz @ 1Hz Intermittent | T 2 | T 5 |
T 12 | ↓ | 800/1000Hz @ 0.875Hz Alternating | T 4 | T 5 |
T 13 | ↓ | 2400Hz @ 1Hz Intermittent | T 15 | T 5 |
T 14 | ↓ | 800Hz 0.25sec on, 1 sec off Intermittent | T 4 | T 5 |
T 15 | ↓ | 800Hz Continuous | T 2 | T 5 |
T 16 | ↓ | 660Hz 150mS on, 150mS off Intermittent | T 18 | T 5 |
T 17 | ↓ | 544Hz (100mS)/440Hz (400mS) - NF S 32-001 | T 2 | T 27 |
T 18 | ↓ | 660Hz 1.8sec on, 1.8sec off Intermittent | T 2 | T 5 |
T 19 | ↓ | 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 | T 2 | T 5 |
T 20 | ↓ | 660Hz Continuous | T 2 | T 5 |
T 21 | ↓ | 554Hz/440Hz @ 1Hz Alternating | T 2 | T 5 |
T 22 | ↓ | 544Hz @ 0.875 sec. Intermittent | T 2 | T 5 |
T 23 | ↓ | 800Hz @ 2Hz Intermittent | T 6 | T 5 |
T 24 | ↓ | 800/1000Hz @ 50Hz Sweeping | T 29 | T 5 |
T 25 | ↓ | 2400/2900Hz @ 50Hz Sweeping | T 29 | T 5 |
T 26 | ↓ | Bell | T 2 | T 15 |
T 27 | ↓ | 554Hz Continuous | T 26 | T 5 |
T 28 | ↓ | 440Hz Continuous | T 2 | T 5 |
T 29 | ↓ | 800/1000Hz @ 7Hz Sweeping | T 7 | T 5 |
T 30 | ↓ | 300Hz Continuous | T 2 | T 5 |
T 31 | ↓ | 660/1200Hz @ 1Hz Sweeping | T 26 | T 5 |
T 32 | ↓ | Two T chime. | T 26 | T 15 |
T 33 | ↓ | 745Hz @ 1Hz Intermittent | T 2 | T 5 |
T 34 | ↓ | 1000 & 2000Hz @ 0.5 sec Alternating - Singapore | T 38 | T 45 |
T 35 | ↓ | 420Hz @ 0.625 sec Australian Alert | T 36 | T 5 |
T 36 | ↓ | 500-1200Hz 3.75sec /0.25sec. Australian Evac. | T 35 | T 5 |
T 37 | ↓ | 1000Hz Continuous - PFEER Toxic Gas | T 9 | T 45 |
T 38 | ↓ | 2000Hz Continuous | T 34 | T 45 |
T 39 | ↓ | 800Hz 0.25sec on, 1 sec off Intermittent | T 23 | T 17 |
T 40 | ↓ | 544Hz (100mS)/440Hz (400mS) - NF S 32-001 | T 31 | T 27 |
T 41 | ↓ | Motor Siren - slow rise to 1200 Hz | T 2 | T 5 |
T 42 | ↓ | Motor Siren - slow rise to 800 Hz | T 2 | T 5 |
T 43 | ↓ | 1200 Hz Continuous | T 2 | T 5 |
T 44 | ↓ | Motor Siren - slow rise to 2400 Hz | T 2 | T 5 |
T 45 | ↓ | 1KHz 1s on, 1s off Intermittent - PFEER Gen. Alarm | T 38 | T 34 |
Country specific or custom tone configurations and alarm frequencies are available upon request. |