IFM
|
Code: TN2511
Description: Temperature sensor with display
(TN2531 is replaced by TN2511)
|
KINETROL
|
Model: 124-100W
DA ACTUATOR MODEL 12 WITH LOW TEMPERATURE UNIT
|
KINETROL
|
Model: 074-004UV02000M
(old 074-004U002000M)
07 VLS LIMIT SWITCH BOX (2xV3 SPDT SWITCHES) AND CONE MONITOR
|
KINETROL
|
Model: DP3C01
P3 PRINTED CIRCUIT BOARD
|
Matsui
|
Mold Temperature Controller
MC5-G1-25H120
Heater: 4kW
Operating Temp.: Supply Water + 10℃- 120℃
Flow Rate: 35L/min @ 1bar (50 Hz)
Pump Capacity: 0.3 kW
Water Supply : 20~ L/min
Supply Pressure: 0.2~0.3 Mpa
Weight: 40 kg
Manifold: 2 way
Dimension of Equipment: 232×563×524
<Option>
Buzzer
Hose Set
|
Matsui
|
Mold Temperature Controller
MC5-G1-55H120
Heater: 6kW
Operating Temp.: Supply Water + 10℃- 120℃
Flow Rate: 35L/min @ 1bar (50 Hz)
Pump Capacity: 0.6 kW
Water Supply : 55 L/min 1 bar 50 Hz
Supply Pressure: 0.2~0.3 Mpa
Weight: 50 kg
Manifold: 4 way
Dimension of Equipment: 232×627×564
<Option>
Buzzer
Hose Set
|
Metrix
|
Mech Switch 5550-411-041
Mechanical Vibration Switch Sensor
Hazard Rating - ATEX, IECEx Flame Proof, Ex d IIB + H2, T6
Contacts - SPDT
Full Scale Range - 5 g
Reset Coil & Start Up Delay - None
Wiring Entry/Mounting Plate - M20 X 1.5; METRIX 5097 / VS-2-EX / 366
Environmntal Rating - NEMA 4X, IP 66
|
Metrix
|
Mech Switch 5550-421-040
Mechanical Vibration Switch Sensor
Hazard Rating - ATEX, IECEx Flame Proof, Ex d IIB + H2, T6
Contacts - DPDT
Full Scale Range - 5 g
Reset Coil & Start Up Delay - None
Wiring Entry/Mounting Plate - M20 X 1.5; METRIX 5097 / VS-2-EX / 366
Environmntal Rating - NEMA 4, IP 66
|
MOXA
|
Model: IKS-6728A-4GTXSFP-HV-T
Modular managed Ethernet switch with 8 10/100BaseT(X) ports, 4 10/100/1000BaseT(X) or 100/1000BaseSFP combo ports, and 2 slots for fast Ethernet modules, front cabling, 1 isolated power supply ( 85-264 VAC), -40 to 75°C
|
MOXA
|
Model: IKS-6728A-8PoE-4GTXSFP-HV-T
Modular managed Ethernet switch with 8 10/100BaseT(X) PoE/PoE+ ports, 4 10/100/1000BaseT(X) or 100/1000BaseSFP combo ports, and 2 slots for fast Ethernet modules, front cabling, 1 isolated power supply ( 85-264 VAC), -40 to 75°C
|
MOXA
|
Model: EDS-205A
Unmanaged Ethernet switch with 5 10/100BaseT(X) ports, -10?to?60°C operating?temperature
|
MOXA
|
Model: Mgate 5114
1-port Modbus/IEC101 to IEC104 gateway, 0 to 60°C operating temperature
|
MOXA
|
Model: Mgate 5109
1-port Modbus-to-DNP3 gateway, 0 to 60°C operating temperature
|
MOXA
|
Model: EDS-P510A-8PoE-2GTXSFP-T
Managed Ethernet PoE Switch with 8 PoE+ ports, 2 combo gigabit Ethernet ports, -40 to 75°C
|
MOXA
|
Model: CBL-M62M9x8-100
Cable/CBL-M62M9x8-100
|
MOXA
|
Model: CP-168U
8 Port UPCI Board, RS-232
|
MOXA
|
Model: EDS-608
Compact managed Ethernet switch system with 2 slots for 4-port fast Ethernet interface modules, for a total of up to 8 ports, 0 to 60°C operating temperature
|
MOXA
|
Model: EDS-616
Compact managed Ethernet switch system with 4 slots for 4-port fast Ethernet interface modules, for a total of up to 16 ports, 0 to 60°C operating temperature
|
MOXA
|
Model: IMC-101-S-SC
Industrial Media Converter, single mode, SC, 40 km, 0 to 60°C
|
MOXA
|
Model: CN2650I-8-2AC
8 ports RS-232/422/485 Terminal server with DB9 connector, Dual 100-200VAC input with adapter with 2 KV isolation
|
MOXA
|
Model: ICF-1150-S-SC
Industrial RS-232/422/485 to Fiber Optic Converter, SC Single mode
|
MOXA
|
Model: ICF-1150-S-SC-T
Industrial RS-232/422/485 to Fiber Optic Converter, SC Single mode, -40 to 85 ℃
|
MTS Sensor
|
Ordering code : RHM0600MD531P102
Temposonics® R-Series
|
MTS Sensor
|
Ordering code : 201542-2
The standard ring magnet
|
MTS Sensor
|
Ordering code : 400633
Magnet spacer
|
MTS Sensor
|
Code: RH5MA1450M01R021A100
Temposonics® R-Series V Rod
Note: RHM1450MR021A01 is obsoleted
|
MTS Sensor
|
Part : 201542-2
Magnet
|
NOHKEN
|
Model: PLU2200F2
Ultrasonic level meter
|
SICK
|
Code: 1030014
Description :ATM60-P1H13X13
Absolute encoders
|
SICK
|
Code: 2029225
Description: AD-ATM60-KA3PR
Adaptor
|
SICK
|
Code: 1046135
Description: LMS511-10100 PRO
2D LiDAR sensors
|
Siemens
|
Model : 7MB2335-0NH16-3AA1
ULTRAMAT 23 Gas Analyzer
Made in France
|
STS SENSOR
|
Code: ATM.1ST/N 119499
Description: Level Transmitter
Housing material: Titanium
Pressure type:Absolute
Pressure range: 900 ... 2200 mbar
Overpressure: 3xFS
Process connection: G 1/2 M, bore Ø 14 mm
Electrical connection: FEP cable, level
Cable length [m]: 6
Output signal: 4 ... 20 mA
Supply voltage: 9 ... 33 V DC
Connection configuration: white:+Vin yellow:Pout
Maximum process temperature: 50°C
Accuracy : <=+/- 0.25% FS
Compensated temperature range: -5 ... 50°C
Total error band: <=+/- 0.3% FS (max.)
Seals: Viton
Medium: Not specified by customer
Special feature 1: Single calibration certificates for each transmitter
Old part number: ATM.1ST/N2.9917.2105.44.UK
|
STS SENSOR
|
Code: ART00069
Description: FEP cable, black
|
Stucke Group
|
Model SYMAP® ECG
Engine Control + Generator Protection
|
Tougu Denki
|
Model : DS-7
Sensor
|
Vaisala
|
Code: DM70 A0A0A0B1
Hand-held Dewpoint Meter
No Indicator
Dewpoint probe for MI70 indicator, higher Td's
No Probe Accessories
NO Connection Cable to a Transmitter
English User´s Guide DM70
|
Vogel
|
Replaced by: DSA1-S03W-1M 1A (000001940404) Pressure Sensor
Pressure switch 3 bar
(DS-W3-4 is discontinued)
|
Vogel
|
Model: 213-870F (000002191881)
Screen filter 160µ
|